datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Aiwa AM-F70, AM-F65

Aiwa AM-F70, AM-F65 free download

Audio equipment,digital audio, home audio, professional audio systems service manuals and repair information

File information:
File name:Serv_Tec_Inf_©_.pdf
[preview AM-F70, AM-F65]
Size:77 kB
Extension:PDF
Mfg:Aiwa
Model:AM-F70, AM-F65 🔎
Original:G-99-079-E1 🔎
Descr:Service Technical Information - Guasto: Changes of component values in motor drive circuit.
Group:Electronics > Consumer electronics > Audio
Uploaded:05-01-2009
User:salvacolnome
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Serv_Tec_Inf_©_.pdf

1/1 Service Technical Information MODEL NO. AM -F70 / F65 SUBJECT Changes of component values in motor -drive circuit REF.No. :G - 99 - 079 - E1 DATE :30. AUG. 2000 REVISION : Added confirming the thread operation of pick up in Countermeasure 4 A fault may occur in IC400 or C430 of the models concerned. For avoiding the fault, component values of L415 and L416 shall be changed. L415 100µ H 330µ H , L416 47µ H 100µ H 1) Remove L416 (47 µ H). 2) Remove the coil of L415 (100µ H), and mount the coil onto the land of L416. 3) Mount a 330 µH coil onto the land of L415. 4) Start the TEST MODE (P -ON with the SYNCHRO SW set to OFF), and confirm the SLED operation of the pick up by pressing F - SKIP and B- SKIP. -The countermeasure is complete if the SLED operation of the pick up is smooth. -If the SLED operation of the pick up is not smooth, change L416 back to 47 µH. Complete the countermeasure after checking again that there is no abnormality in the SLED operation of the pick up. The 100 µH coil used on L415 will be mounted on land of L416. Order a 330 µH coil only. PWB, MAIN BOTTOM SIDE IC400 C430 L416 TEST LAND L415 Ref. L415 G - R - Parts Code 87 -A50- 355 - 080 Code No. - Description C -COIL,330 µ H Access Code - Modified Ser. No. - Remarks - Parts Schedule -

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
AIWA hfe aiwa av-d97 service - AIWA hfe aiwa hs-p08 g08 g500 service en - AIWA aiwacs130131 - AIWA hfe aiwa ca-dw247 dw257 service revision en - AIWA hfe aiwa mm-vx100 service en - AIWA aiwa ct-fr925m, ct-fx525m - AIWA hfe aiwa z-r550 service simple en -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : QSC USA Series

script execution: 0.03 s